Glossary

Plain-language meanings for terms used in ForensiLab.

Absorbance
A measure of how much light a sample absorbs at a given wavelength. UV-Vis instruments report it.
Analyte
The substance a test is looking for or measuring.
Baseline
The flat part of a trace where only background signal is present. Peaks rise from it, and a drifting or noisy baseline makes them harder to read.
Carrier gas
The inert gas that sweeps a vaporised sample through the column in gas chromatography.
Carryover
Traces of one sample that remain in the system and show up in the next run. A blank run is used to check for it.
Chain of custody
The written record of who held a specimen and when, from collection to the lab. A gap in it can make a result unusable as evidence.
Chromatogram
A plot of detector signal against time, with one peak for each compound that leaves the column.
Confirmation test
A more specific second test, such as GC-MS, that identifies a substance after a screening test points to it.
Cuvette
The small transparent holder for a liquid sample in a UV-Vis instrument.
Detection window
How long after use a substance can still be found in a given specimen.
Immunoassay
A quick screening test in which antibodies bind to a drug or its metabolites. It can cross-react with similar compounds, so positives need confirming.
Internal standard
A known compound added to every sample so that losses and instrument changes can be corrected when measuring the analyte.
Mass spectrum
A plot of the ions a mass spectrometer detects, sorted by mass-to-charge ratio. Its pattern helps identify a compound.
Metabolite
A compound the body makes when it breaks down a drug. Tests often look for metabolites because they last longer or show that the drug was taken.
Mobile phase
The liquid that carries the sample through the column in HPLC.
Peak
A rise in the signal as a compound passes the detector. Its position helps identify the compound, and its size relates to the amount.
Postmortem redistribution
The movement of drugs between tissues and blood after death, which can change measured concentrations depending on where and when the specimen is taken.
Preservative
A chemical added to a specimen to stop the analyte being made or destroyed by microbes or enzymes before testing.
Retention time
How long a compound takes to travel through the column and reach the detector. Under fixed conditions, it helps identify the compound.
Screening test
A fast first test that sorts samples into likely negative and possible positive. It is not proof on its own.
Split and splitless injection
Two ways of loading a gas chromatograph. Split sends only part of the sample onto the column, and splitless sends nearly all of it.
Stationary phase
The coating or packing inside a column that holds back compounds to different degrees, which separates them.
Vitreous humour
The clear gel inside the eye. It is a useful postmortem specimen because it is well protected and changes less than blood after death.