Glossary
Plain-language meanings for terms used in ForensiLab.
- Absorbance
- A measure of how much light a sample absorbs at a given wavelength. UV-Vis instruments report it.
- Analyte
- The substance a test is looking for or measuring.
- Baseline
- The flat part of a trace where only background signal is present. Peaks rise from it, and a drifting or noisy baseline makes them harder to read.
- Carrier gas
- The inert gas that sweeps a vaporised sample through the column in gas chromatography.
- Carryover
- Traces of one sample that remain in the system and show up in the next run. A blank run is used to check for it.
- Chain of custody
- The written record of who held a specimen and when, from collection to the lab. A gap in it can make a result unusable as evidence.
- Chromatogram
- A plot of detector signal against time, with one peak for each compound that leaves the column.
- Confirmation test
- A more specific second test, such as GC-MS, that identifies a substance after a screening test points to it.
- Cuvette
- The small transparent holder for a liquid sample in a UV-Vis instrument.
- Detection window
- How long after use a substance can still be found in a given specimen.
- Immunoassay
- A quick screening test in which antibodies bind to a drug or its metabolites. It can cross-react with similar compounds, so positives need confirming.
- Internal standard
- A known compound added to every sample so that losses and instrument changes can be corrected when measuring the analyte.
- Mass spectrum
- A plot of the ions a mass spectrometer detects, sorted by mass-to-charge ratio. Its pattern helps identify a compound.
- Metabolite
- A compound the body makes when it breaks down a drug. Tests often look for metabolites because they last longer or show that the drug was taken.
- Mobile phase
- The liquid that carries the sample through the column in HPLC.
- Peak
- A rise in the signal as a compound passes the detector. Its position helps identify the compound, and its size relates to the amount.
- Postmortem redistribution
- The movement of drugs between tissues and blood after death, which can change measured concentrations depending on where and when the specimen is taken.
- Preservative
- A chemical added to a specimen to stop the analyte being made or destroyed by microbes or enzymes before testing.
- Retention time
- How long a compound takes to travel through the column and reach the detector. Under fixed conditions, it helps identify the compound.
- Screening test
- A fast first test that sorts samples into likely negative and possible positive. It is not proof on its own.
- Split and splitless injection
- Two ways of loading a gas chromatograph. Split sends only part of the sample onto the column, and splitless sends nearly all of it.
- Stationary phase
- The coating or packing inside a column that holds back compounds to different degrees, which separates them.
- Vitreous humour
- The clear gel inside the eye. It is a useful postmortem specimen because it is well protected and changes less than blood after death.