Carbon monoxide
CO, Carbonic oxide, Carbon(II) oxide
Text review: Needs verification · 0 of 7 values verified
Overview
- Category
- Toxic gas
- Class
- Chemical asphyxiant
- Mechanism
- Colourless, odourless gas from incomplete combustion. It binds haemoglobin far more avidly than oxygen to form carboxyhaemoglobin (COHb), which reduces oxygen-carrying capacity and shifts the oxygen-haemoglobin dissociation curve so that remaining oxygen is released less readily, producing tissue hypoxia. It also binds myoglobin and inhibits cytochrome c oxidase, which adds to heart and brain injury.
Concentrations
Needs verification0 of 4 values verified
Notes
- aBlood (peripheral) — Symptoms track COHb only loosely. Older people and those with heart or lung disease can be harmed or die at lower saturations. Oxygen therapy and resuscitation lower COHb, so read results in context.
Detection windows
Needs verification| Specimen | Window |
|---|---|
| Blood (peripheral)a | Not yet added |
Notes
- aBlood (peripheral) — COHb falls once the person leaves the source, and falls faster with oxygen; a hospital sample may under-represent exposure at the scene.
Metabolites
No metabolites recorded yet.
Recommended specimens
Collection and storage
Needs verificationBlood (peripheral)
- Container
- Plastic screw-cap container for peripheral blood, filled and tightly sealed to limit headspace
- Preservative
- Fluoride (sodium or potassium)
- Storage temperature
- Not yet added
- Note
- Reported to be relatively stable when kept cold. The collection guideline's general rule makes fluoride mandatory for peripheral blood, so it is followed here; no source read gives CO-specific preservative advice. CO-specific handling matters most: fill the container and seal it tightly to limit headspace, applying the guideline's rule for volatile substances to a gas by analogy (the guideline gives no CO-specific container advice). The ATSDR research method collects blood into a heparinised syringe for COHb analysis; that is a clinical and research collection method and is not the forensic rule followed here. The guideline notes the spleen as an alternative when blood is unavailable, for example in fire deaths, because carbon monoxide accumulates in erythrocytes.
Blood (cardiac)
- Container
- Plastic screw-cap container for cardiac blood, filled and tightly sealed to limit headspace
- Preservative
- None specified
- Storage temperature
- Not yet added
- Note
- Same by-analogy container advice as peripheral blood. The guideline says a preservative is not mandatory for cardiac blood and that the sampling site should be on the label, the right heart chamber being preferred.
Analytical methods
- Detector tubes (field screening of air)ScreeningField use for atmosphere, not a laboratory blood method.
- Multi-wavelength CO-oximetryQuantificationAutomated measurement of haemoglobin derivatives, used clinically and in laboratories.
- UV-visible spectrophotometry of COHbQuantificationPractise on the UV-VIS simulatorThe most widely used laboratory approach for COHb.
- Gas chromatography of released COConfirmationATSDR describes adding potassium ferricyanide to blood to release bound CO, injecting it into a gas chromatograph with a reduction gas detector, and calls the method selective, sensitive and highly reliable, especially at low levels. It also notes that some CO-oximeters overestimate low COHb compared with GC.
Interpretation notes
Fire deaths
In fire victims assess cyanide and methaemoglobin as well as COHb, because smoke exposes victims to a mixture of toxicants at once.
Post-resuscitation and oxygen
Oxygen therapy and CPR lower COHb, so a low value in a treated patient does not exclude significant exposure.
Postmortem formation
CO can form after death through putrefaction or prolonged immersion. Body-cavity fluids should not be used for CO measurement when putrefaction is advanced.
Autopsy findings
Cherry-red discolouration is characteristic but other findings are non-specific, so COHb measurement carries the diagnosis.
Clinical measurement
ATSDR names CO-oximeters, found in hospitals and clinical laboratories, as the simple test for blood CO.
Sources
- [1]National Center for Biotechnology Information. PubChem compound record: Carbon monoxide (synonyms list, fetched via PubChem PUG REST). https://pubchem.ncbi.nlm.nih.gov/rest/pug/compound/name/carbon%20monoxide/synonyms/TXT
- [2]Kinoshita H, Türkan H, Vucinic S, Naqvi S, Bedair R, Rezaee R, Tsatsakis A. Carbon monoxide poisoning. Toxicology Reports. 2020;7:169-173. doi:10.1016/j.toxrep.2020.01.005. (2020) https://pmc.ncbi.nlm.nih.gov/articles/PMC6992844
- [3]Agency for Toxic Substances and Disease Registry. ToxFAQs for Carbon Monoxide. Page last reviewed 13 December 2012. (2012) https://wwwn.cdc.gov/TSP/ToxFAQs/ToxFAQsDetails.aspx?faqid=1163&toxid=253
- [4]Agency for Toxic Substances and Disease Registry. Toxicological Profile for Carbon Monoxide. Atlanta: U.S. Department of Health and Human Services; June 2012. (2012), 7. Analytical Methods, 7.1 Biological Materials; Table 7-1 https://www.atsdr.cdc.gov/toxprofiles/tp201.pdf
- [5]Dinis-Oliveira RJ, Vieira DN, Magalhães T. Guidelines for collection of biological samples for clinical and forensic toxicological analysis. Forensic Sciences Research. 2017;1(1):42-51. doi:10.1080/20961790.2016.1271098 (2017), Post-mortem samples; Kits: containers, labelling and toxicological request form https://pmc.ncbi.nlm.nih.gov/articles/PMC6197137/
- Text review
- Needs verification
- Values
- 0 of 7 values verified
- Last reviewed
- —
- Note
- Gas chromatography entry is sourced to the ATSDR carbon monoxide profile. Still unsupported: no source read gives CO-specific container or preservative advice, so fluoride follows the guideline's general peripheral-blood rule and the sealed, filled container is the volatile rule applied by analogy.