Skip to content

Carbon monoxide

CO, Carbonic oxide, Carbon(II) oxide

CAS 630-08-0Toxic gasChemical asphyxiant
Educational reference only — not for casework interpretation. Verify every value against primary sources.

Text review: Needs verification · 0 of 7 values verified

Overview

Category
Toxic gas
Class
Chemical asphyxiant
Mechanism
Colourless, odourless gas from incomplete combustion. It binds haemoglobin far more avidly than oxygen to form carboxyhaemoglobin (COHb), which reduces oxygen-carrying capacity and shifts the oxygen-haemoglobin dissociation curve so that remaining oxygen is released less readily, producing tissue hypoxia. It also binds myoglobin and inhibits cytochrome c oxidase, which adds to heart and brain injury.

Concentrations

Needs verification

0 of 4 values verified

0 of 4 values verified
SpecimenTherapeuticToxicLethal
Blood (peripheral)aNot applicableaNot yet addedNot yet added
Blood (cardiac)Not applicableNot yet addedNot yet added

Notes

  • aBlood (peripheral) — Symptoms track COHb only loosely. Older people and those with heart or lung disease can be harmed or die at lower saturations. Oxygen therapy and resuscitation lower COHb, so read results in context.

Detection windows

Needs verification
SpecimenWindow
Blood (peripheral)aNot yet added

Notes

  • aBlood (peripheral) — COHb falls once the person leaves the source, and falls faster with oxygen; a hospital sample may under-represent exposure at the scene.

Metabolites

No metabolites recorded yet.

Recommended specimens

Collection and storage

Needs verification

Blood (peripheral)

Container
Plastic screw-cap container for peripheral blood, filled and tightly sealed to limit headspace
Preservative
Fluoride (sodium or potassium)
Storage temperature
Not yet added
Note
Reported to be relatively stable when kept cold. The collection guideline's general rule makes fluoride mandatory for peripheral blood, so it is followed here; no source read gives CO-specific preservative advice. CO-specific handling matters most: fill the container and seal it tightly to limit headspace, applying the guideline's rule for volatile substances to a gas by analogy (the guideline gives no CO-specific container advice). The ATSDR research method collects blood into a heparinised syringe for COHb analysis; that is a clinical and research collection method and is not the forensic rule followed here. The guideline notes the spleen as an alternative when blood is unavailable, for example in fire deaths, because carbon monoxide accumulates in erythrocytes.

Blood (cardiac)

Container
Plastic screw-cap container for cardiac blood, filled and tightly sealed to limit headspace
Preservative
None specified
Storage temperature
Not yet added
Note
Same by-analogy container advice as peripheral blood. The guideline says a preservative is not mandatory for cardiac blood and that the sampling site should be on the label, the right heart chamber being preferred.

Analytical methods

  • Detector tubes (field screening of air)ScreeningField use for atmosphere, not a laboratory blood method.
  • Multi-wavelength CO-oximetryQuantificationAutomated measurement of haemoglobin derivatives, used clinically and in laboratories.
  • UV-visible spectrophotometry of COHbQuantificationPractise on the UV-VIS simulatorThe most widely used laboratory approach for COHb.
  • Gas chromatography of released COConfirmationATSDR describes adding potassium ferricyanide to blood to release bound CO, injecting it into a gas chromatograph with a reduction gas detector, and calls the method selective, sensitive and highly reliable, especially at low levels. It also notes that some CO-oximeters overestimate low COHb compared with GC.

Interpretation notes

Fire deaths

In fire victims assess cyanide and methaemoglobin as well as COHb, because smoke exposes victims to a mixture of toxicants at once.

Post-resuscitation and oxygen

Oxygen therapy and CPR lower COHb, so a low value in a treated patient does not exclude significant exposure.

Postmortem formation

CO can form after death through putrefaction or prolonged immersion. Body-cavity fluids should not be used for CO measurement when putrefaction is advanced.

Autopsy findings

Cherry-red discolouration is characteristic but other findings are non-specific, so COHb measurement carries the diagnosis.

Clinical measurement

ATSDR names CO-oximeters, found in hospitals and clinical laboratories, as the simple test for blood CO.

Sources

  1. [1]National Center for Biotechnology Information. PubChem compound record: Carbon monoxide (synonyms list, fetched via PubChem PUG REST). https://pubchem.ncbi.nlm.nih.gov/rest/pug/compound/name/carbon%20monoxide/synonyms/TXT
  2. [2]Kinoshita H, Türkan H, Vucinic S, Naqvi S, Bedair R, Rezaee R, Tsatsakis A. Carbon monoxide poisoning. Toxicology Reports. 2020;7:169-173. doi:10.1016/j.toxrep.2020.01.005. (2020) https://pmc.ncbi.nlm.nih.gov/articles/PMC6992844
  3. [3]Agency for Toxic Substances and Disease Registry. ToxFAQs for Carbon Monoxide. Page last reviewed 13 December 2012. (2012) https://wwwn.cdc.gov/TSP/ToxFAQs/ToxFAQsDetails.aspx?faqid=1163&toxid=253
  4. [4]Agency for Toxic Substances and Disease Registry. Toxicological Profile for Carbon Monoxide. Atlanta: U.S. Department of Health and Human Services; June 2012. (2012), 7. Analytical Methods, 7.1 Biological Materials; Table 7-1 https://www.atsdr.cdc.gov/toxprofiles/tp201.pdf
  5. [5]Dinis-Oliveira RJ, Vieira DN, Magalhães T. Guidelines for collection of biological samples for clinical and forensic toxicological analysis. Forensic Sciences Research. 2017;1(1):42-51. doi:10.1080/20961790.2016.1271098 (2017), Post-mortem samples; Kits: containers, labelling and toxicological request form https://pmc.ncbi.nlm.nih.gov/articles/PMC6197137/
Text review
Needs verification
Values
0 of 7 values verified
Last reviewed
—
Note
Gas chromatography entry is sourced to the ATSDR carbon monoxide profile. Still unsupported: no source read gives CO-specific container or preservative advice, so fluoride follows the guideline's general peripheral-blood rule and the sealed, filled container is the volatile rule applied by analogy.

Used in cases

Back to the referenceSpecimen collection guides